ZyXEL Communications U-1496 series Specifications

Browse online or download Specifications for Networking ZyXEL Communications U-1496 series. ZyXEL Communications U-1496 series Specifications User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Installation & Operation

ericssonzericssonzInstallation & OperationEDACSSite Interface Module (SIM)

Page 2 - E/LZB 119 1889 R1A NOTICES

AE/LZB 119 1889 R1A INSTALLATION10 Fasten the brackets to the back mounting rails of anenclosed cabinet or open rack using the followinghardware:• (

Page 3 - CONTENTS AE/LZB 119 1889 R1

INSTALLATION AE/LZB 119 1889 R1A11qConnect DC Power Supply Power Cord (skip thisstep if the site is DC powered): Plug the AC power cord(attached to th

Page 4 - SPECIFICATIONS

AE/LZB 119 1889 R1A INSTALLATION12MODEM SETUPIf a pair of modems is used to connect the SIM to theSystem Manager, the modems must be configured for th

Page 5 - DESCRIPTION

INSTALLATION AE/LZB 119 1889 R1A13Programming CableSerial COM PortJ4 J3RPM 113 2514Personal ComputerIBM-CompatableFigure 4 - SIM Programming Setup2.

Page 6 - ENHANCED FEATURES

AE/LZB 119 1889 R1A INSTALLATION14press the Enter key. The SIM should respond inless than 10 seconds by displaying the word OK. Ifthe word OK is not

Page 7 - INSTALLATION

INSTALLATION AE/LZB 119 1889 R1A15To change the amount of time between each step in thesequence, type set∧∧miscP,displayOffTime∧∧LX (replacingX with t

Page 8 - SITE DATABASE SETUP

AE/LZB 119 1889 R1A OPERATION16OPERATIONENHANCED FEATURESThe operation of the additional features provided by asite containing Enhanced GETCs (using R

Page 9 - SIM EQUIPMENT MOUNTING

OPERATION AE/LZB 119 1889 R1A17Confirmed Call by GIDThe GETC uses the Confirmed Call Enable parameterin the GID database to determine if a group call

Page 10

AE/LZB 119 1889 R1A OPERATION18Site Activity MonitoringThe SIM monitors the activities of the site bymonitoring the activity information on the BSL.

Page 11

MAINTENANCE AE/LZB 119 1889 R1A19MAINTENANCENote that in the character strings used to programthe SIM, the symbol ∧∧ is used for a single spacebetween

Page 12 - SIM SETUP

AE/LZB 119 1889 R1A NOTICESCopyright July 1996, Ericsson Inc.2NOTICE!This Manual covers Ericsson and General Electric products manufactured and sold

Page 13 - IBM-Compatable

AE/LZB 119 1889 R1A MAINTENANCE20• From the Download pull-down menu, selectApplication. Next, select the new applicationsoftware program file (gener

Page 14

GLOSSARY AE/LZB 119 1889 R1A21GLOSSARYBackup Serial Line ... The Backup Serial Line (BSL) is a data bus connected

Page 15

AE/LZB 119 1889 R1A PARTS LISTS22PARTS LISTSSIM OPTION(Actual parts supplied depend on how option is ordered.)ITEM PART NO. DESCRIPTION EACHSITEDCPOWE

Page 16 - OPERATION

PARTS LISTS AE/LZB 119 1889 R1A23

Page 17 - OPERATION AE/LZB 119 1889 R1

AE/LZB 119 1889 R1A PARTS LISTS24SIM Shelf AssemblySXK 107 3826ITEM QTY PART NO. DESCRIPTION1 1 SXA 120 4207 SIM Shelf, sheet metal only2 1 BKV 301 21

Page 18 - E/LZB 119 1889 R1A OPERATION

PARTS LISTS AE/LZB 119 1889 R1A25CONTROLLER MODULE ASSEMBLYKEP 813 72ITEM QTY PART NO. DESCRIPTION1 1 SXA 120 4185/2 Controller Chassis, sheet metal o

Page 19 - MAINTENANCE

AE/LZB 119 1889 R1A INTERCONNECTION DIAGRAMSInterconnection DiagramEnhanced Basic EDACS Site (AC Powered)26SERIAL MODULEDownlink GETCJ14J102TB10EDACS

Page 20 - AND POST-MORTEM INFORMATION

INTERCONNECTION DIAGRAMS AE/LZB 119 1889 R1AInterconnection DiagramEnhanced Basic EDACS Site (AC Powered)27

Page 21 - GLOSSARY

AE/LZB 119 1889 R1A INTERCONNECTION DIAGRAMSInterconnection DiagramEnhanced Basic EDACS Site (DC Powered)28SERIAL MODULEDownlink GETCJ14J102TB10EDACS

Page 22 - PARTS LISTS

INTERCONNECTION DIAGRAMS AE/LZB 119 1889 R1AInterconnection DiagramEnhanced Basic EDACS Site (DC Powered)29

Page 23

CONTENTS AE/LZB 119 1889 R1A3TABLE OF CONTENTSPageSPECIFICATIONS ...

Page 24 - ITEM QTY PART NO. DESCRIPTION

AE/LZB 119 1889 R1A INTERCONNECTION DIAGRAMSInterconnection DiagramEnhanced SCAT Site (AC Powered)30SERIAL MODULEDownlink GETCJ14J102TB10EDACS Interfa

Page 25

INTERCONNECTION DIAGRAMS AE/LZB 119 1889 R1AInterconnection DiagramEnhanced SCAT Site (AC Powered)31

Page 26 - Interconnection Diagram

AE/LZB 119 1889 R1A INTERCONNECTION DIAGRAMSInterconnection DiagramEnhanced SCAT Site (DC Powered)32SERIAL MODULEDownlink GETCJ14J102TB10EDACS Interfa

Page 27

INTERCONNECTION DIAGRAMS AE/LZB 119 1889 R1AInterconnection DiagramEnhanced SCAT Site (DC Powered)33

Page 28

Ericsson Inc.Private Radio SystemsMountain View RoadLynchburg, Virginia 24502 AE/LZB 119 1889 R1A1-800-528-7711 (Outside USA, 804-528-7711) Printed in

Page 29

AE/LZB 119 1889 R1A FIGURES / SPECIFICATIONS4LIST OF FIGURESPageFigure 1 - Standard Mounting Location...

Page 30

INTRODUCTION / DESCRIPTION AE/LZB 119 1889 R1A5INTRODUCTIONThe Site Interface Module (SIM), when used withGETCs with Enhanced Features enabled, adds e

Page 31

AE/LZB 119 1889 R1A INTRODUCTION / DESCRIPTION6ENHANCED FEATURESA site containing GETCs with Enhanced Featuresenabled (using Release 6 or later softwa

Page 32

INSTALLATION AE/LZB 119 1889 R1A7INSTALLATIONSYSTEM REQUIREMENTSIf you are installing a SIM in an existing EDACSsystem, a minimum hardware and softwar

Page 33

AE/LZB 119 1889 R1A INSTALLATION8SITE DATABASE SETUPThe following parameters, configurable through theSystem Manager, affect the operation of the SIM

Page 34 - Mountain View Road

INSTALLATION AE/LZB 119 1889 R1A9SIM EQUIPMENT MOUNTINGUse this procedure to mount the SIM equipment in anexisting system. If the SIM equipment was m

Comments to this Manuals